PERSONAL SAFETY
|
Toxic Gas and Oxygen Indicator |
Indoor Air Quality
Test Kit

Applications
Chemical
Hazardous Materials
Oil and Gas
Hazards
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
Offers an
inexpensive way to test the air for contaminants, so you can
take the necessary measures to protect your health and that
of your associates. Consists of a Kwik-Draw sampling pump
and a box of detector tubes (two each). Each item can also
be purchased separately. |
Industry Action Sets

Features and Benefits
For use with
MSA detector tube pumps
Specific detector tubes packaged in groups for specific
industry needs
Choices of industry action sets include agricultural, pulp
and paper, pharmaceutical, petroleum, mining, synthetics,
and semiconductor applications
All sets contain twelve tubes
Applications
Electric
Utility
Fire Fighting
Hazardous Materials
Paper & Pulp
Hazards
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH |
Detector Tubes and
Pumps

Features and Benefits
“Go/No Go”
style
Detect nerve, blister, blood, and choking agents
A reliable method of testing more than 170 hazardous gases
and vapors
Specialized kits are available for use in HazMat work and
indoor air quality testing
Applications
BuAgriculture
Chemical
Construction
Domestic Preparedness
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Nuclear
Oil and Gas
Paper & Pulp
Spray Painting
Welding
Hazards
Confined
Space
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH |
Gas-Tester™ II H
Detector Tube Pump

Principles of Operation
An accurate
measurement is obtained because the sample draw procedure
itself is controlled only by the specifications of the pump
and the flow resistance of the detector tube.
Applications
Chemical
Construction
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Oil and Gas
Paper & Pulp
Hazards
Toxic
Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
The
Gas-Tester II H Detector Tube Pump is set for action by
compressing the bellows. A pump stroke is started by
pressing the release button. When the sample (100ml) is
drawn through the tube, the end-of-stroke indicator changes
color. |
HAZMATCAD™ and
HAZMATCAD™ Plus Hazardous Material Chemical Agent Detectors

Applications
Chemical
Domestic Preparedness
Fire Fighting
Gas Detection
General Industry
Hazardous Materials
Hazards
Toxic
Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
The HAZMATCAD
Plus Chemical Agent Detector detects both chemical warfare
agents and selected toxic industrial chemicals (TICs). Both
units are ruggedly constructed, compact and lightweight.
They are also extremely easy to use, requiring no prior
training. A single key press begins automatic sampling and
analysis. Audible and visual alarm messages provide clear
and simple alarm condition display. Offers self-diagnostic
check during rapid warm-up, alphanumeric display with LED
alarms and 8-12 hour operation with rechargeable lithium ion
batteries. Vapor diffusion check source verifies system
performance. RS 232 and IrDA communication ports store up to
eight hours of data. The inlet design protects against dust
and particulate. Kits include a battery charger, belt clip,
two Sony long-life lithium ion rechargeable batteries, a
waterproof carrying case, vapor check source and operating
manual. |
Kwik-Draw® Detector
Tube Pumps

Features and Benefits
Designed for
accurate, one-hand operation and consistent delivery of a
sample draw volume of 100 ml
Includes state-of-the-art end-of-stroke indicator and stroke
counter
Principles of
Operation
Kwik-Draw
detector tube pumps are designed for one-handed operation
and consistent delivery of a sample volume of 100
milliliters (ml). An integral counter helps track the number
of sample pumps.
Applications
Chemical
Construction
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Oil and Gas
Paper & Pulp |
MiniCl02 Responder
Alarm

Principles of Operation
Audible and
visible warnings or alarms are activated when gas
concentrations exceed two preset levels. A "Warning" (W) or
low alarm is activated when a low concentration of chlorine
dioxide is detected. A distinctive pulsing alarm is
activated when a higher concentration is detected. This
"High Alarm" can only be cleared when the concentration
drops below the alarm set point.
Approvals and
Standards
ETL (an OSHA
NRTL); Class 1; Div. 1; Groups A, B, C and D.
Applications
Chemical
Hazardous Materials
Oil and Gas
Paper & Pulp
Water/Wastewater
Hazards
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
Offers
convenient low-level chlorine dioxide monitoring in a
variety of applications. Perfect for use in many industries,
including chemical, food and beverage, HazMat,
petrochemical, pharmaceutical, pulp and paper, semiconductor
and water/wastewater treatment. The alarm has a 0-6 ppm
measuring range, and with only three buttons the alarm is
very easy to use. Weighing less than eight ounces and
running on a commercially available nine-volt battery, it
offers the user the ability to determine peak readings with
the press of a button. For user safety, the MiniClO2
Responder Alarm has a specially designed, time-delay power
button that must be pressed for five seconds to turn the
power off, helping to prevent accidental shutoff during use.
Features a lifetime warranty on most components. |
MiniCl2 Responder Alarm

Principles of Operation
Audible and
visible warnings or alarms are activated when gas
concentrations exceed two preset levels. A "Warning" (W) or
low alarm is activated when a low concentration of chlorine
is detected. A distinctive pulsing alarm is activated when a
higher concentration is detected. This "High Alarm" can only
be cleared when the concentration drops below the alarm set
point.
Approvals and
Standards
ETL (an OSHA
NRTL); Class 1; Div. 1; Groups A, B, C and D.
Applications
Chemical
Hazardous Materials
Oil and Gas
Paper & Pulp
Water/Wastewater
Hazards
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
Offers
convenient low-level chlorine monitoring in a variety of
applications. Perfect in many industries, including
chemical, food and beverage, HazMat, petrochemical,
pharmaceutical, pulp and paper, semiconductor and
water/wastewater treatment. The alarm has a 0-15 ppm
measuring range, and with only three buttons the alarm is
very easy to use. Weighing less than eight ounces and
running on a commercially available nine-volt battery, it
offers the user the ability to determine peak readings with
the press of a button. For user safety, the alarm has a
specially designed, time-delay power button that must be
pressed for five seconds to turn the power off, helping to
prevent accidental shutoff during use. Features a lifetime
warranty on most components. |
PULSAR® + Single-Gas
Detector

Approvals and Standards
Intrinsic
Safety Approvals: Class I, Division 1, Groups A B, C and D.
ATEX II 1 G EEx ia IIC T4. European EMC complies to EN50270.
Applications
Agriculture
Chemical
Construction
Electric Utility
Fire Fighting
Manufacturing
Nuclear
Oil and Gas
Paper & Pulp
Rescue
Water/Wastewater
Welding
Hazards
Confined
Space
Gas Detection
Nuisance Odor
Oxygen Deficiency
Toxic Atmosphere - IDLH
Toxic Atmosphere Non-IDLH
Welding
Product
Information
Detects CO,
H2S or O2, and is ideal for use in confined space monitoring
and for a variety of industrial applications. The durable
design and simplified operation provide dependable
monitoring in even the harshest environments. This unit
features a large gas concentration display that is easy to
read, even in low-light conditions, a replaceable sensor and
battery, simplified autocalibration at the push of a button.
The durable design withstands severe conditions and usage.
The triple alarm system features piercing audio, quadruple
ultra-bright visual and optional vibrating alarms. Strong,
versatile clip designs keep the unit attached during the
roughest use. |
PULSAR® Single-Gas
Detector

Applications
Agriculture
Chemical
Construction
Electric Utility
Fire Fighting
Hazardous Materials
Nuclear
Oil and Gas
Paper & Pulp
Water/Wastewater
Welding
Hazards
Confined
Space
Gas Detection
Oxygen Deficiency
Toxic Atmosphere - IDLH
Toxic Atmosphere Non-IDLH
Welding
Product
Information
Provides
maintenance-free, 24-month monitoring of CO, H2S or O2. With
a unique design and competitive price, it is the clear
choice in single-gas detectors. Requires no field
calibration, battery or sensor replacement. Spring and
suspension attachment clips are standard, keeping the unit
attached during even the roughest use. The unit can be worn
inside or outside a pocket, as well as on the belt or
helmet. A long-life lithium battery offers 33% more capacity
than the competition. A numeric display with characters four
times larger than the competition allows users to count down
service life from 24 months with accuracy and confidence.
Because the PULSAR Single-Gas Detector has a built-in
gas-delivery adapter, no easy-to-misplace accessories are
needed to conduct gas-response tests. |
Toximeter™ II
Automatic Detector Tube Pump

Applications
Chemical
Construction
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Oil and Gas
Paper & Pulp
Hazards
Toxic
Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
Makes the
sampling process easier, allowing the user to preset the
number of pump strokes (from one to 250). Intrinsically
safe, the automatic pump works with all MSA detector tubes
and can also be used as a sampling pump. |
Ventilation Smoke
Tube Kits

Applications
Chemical
Construction
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Oil and Gas
Paper & Pulp
Hazards
Confined
Space
Nuisance Odor
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product
Information
MSA's
ventilation smoke tube kits are for use where controlled
generation of visible smoke is desired in order to determine
the velocity of slow-moving air currents and establish their
direction and flow patterns in shafts, mines and tunnels.
The kits can also be used in commercial buildings and
industrial processing plants to determine velocity and flow
patterns of heating, ventilating and air-conditioning
systems. |

S.O.S. Rubber International
Inc.
20283 State Road 7 Suite #400, Boca Raton, Florida 33498
Tel (561) 237-4247 | Fax (561) 237-4248 | email:
info@sosrubberintl.com
We accept:

|