S.O.S. Rubber International Inc.- We offer for the Industrial Industry, Petroleum Field, Terminals and Contractors equipments such as hoses, firefighting and conveyor belting…

PERSONAL SAFETY

Industrial Gas Masks
Chin-Type Gas Masks

Features and Benefits

Full facepiece respiratory protection against certain gases and particulates
Lightweight aluminum canister
Full line of canisters available

Principles of Operation

Upon inhalation, contaminated air enters the gas mask canister, where it is filtered before reaching the wearer, who breathes in only clean, fresh air.

Approvals and Standards

The MSA Chin-Type gas mask has been certified by the National Institute for Occupational Safety and Health (NIOSH). The specific numbers are shown under ordering information for each mask type.

Applications

Agriculture
Chemical
Electric Utility
Paper & Pulp

Hazards

Toxic Atmosphere Non-IDLH

Product Information

Provides respiratory protection against particulate matter, vapors and gases by means of a lightweight, replaceable canister. The small, oval-shaped aluminum canister and facepiece are designed to permit downward head movement. This comfortable, lightweight model is an alternative to the heavier models and is designed for respiratory protection against a specific gas or group of gases as indicated by canister identification. The gas mask assembly has the following Maximum Use Conditions: Entry - 100% the Permissible Exposure Level; do not exceed the Immediately Dangerous to Life and Health (IDLH) concentration. Escape - contaminant concentrations up to the maximum use concentration of the gas mask (generally 5,000 ppm (0.5%) by volume; see canister selection chart for details), providing there is adequate oxygen (19.5% by volume) to support life. At these upper use conditions, the service time may be as short as 12 minutes. Also available as a belt-mounted version which allows the wearer to attach the canister to a belt clip and uses a corrugated breathing tube to connect the canister to the facepiece.

WARNING: Do not use for fire fighting.

PN Description
492827 BELT ASSY.URETHANE PAPR
817057 GAS MASK,GMA-C-N95 CANSTR
817058 GAS MASK,GMA-C-N95 CANISTER
817059 GAS MASK ASSY,CHIN TYPE,GMC-C-N95,W/CASE
817060 GAS MASK,GMC-C-N95 CANISTER
817061 GAS MASK ASSY,CHIN TYPE,GMF-C-N95,W/CASE
817062 GAS MASK,GMF-C-N95 CANISTER
817063 GAS MASK ASSY,CHIN TYPE,GMD-C-N95,W/CASE
817064 GAS MASK ASSY,CHIN TYPE,GMD-C-N95
817065 GAS MASK ASSY,CHIN TYPE,GML-C-N95,W/CASE
817066 GAS MASK ASSY,CHIN TYPE,GML-C-N95
9961 BELT ASSY,WAIST,NYLON WEBBING,BLACK,52"
Replacement Canisters for Gas Masks

Principles of Operation

Upon inhalation, contaminated air enters the gas mask canister, where it is filtered before reaching the wearer, who breathes in only clean, fresh air.

Approvals and Standards

All MSA gas masks are certified by the National Institute for Occupational Safety and Health (NIOSH). The specific numbers are shown under ordering information for each mask and canister type.

Applications

Agriculture
Chemical
Electric Utility
Hazardous Materials
Oil and Gas
Paper & Pulp

Hazards

Toxic Atmosphere Non-IDLH

Product Information

Depending upon the type and concentration of contaminant and length of service time required, MSA offers three canister models, including Type N or Super-Size, Industrial-Size and Chin-Type. The canisters are seamless to prevent leakage or channeling of gases/vapors past the chemical sorbents, kept fresh by sealing tape on the bottom air intake, which also prevents moisture from entering the canister before use. They are easy to use and store because of their compact oval shape, labeled as to type and limitations and are color-coded for fast and accurate recognition.

PN Description
815993 CANISTER, GAS MASK, CHIN-TYPE, GMD-C-N95
815994 CANISTER,GAS MASK,CHIN TYPE,GMA-C-N95
815995 CANISTER,GAS MASK,CHIN TYPE,GML-C-N95
815996 CANISTER, GAS MASK,CHIN-TYPE, GMC-C-N95
815998 CANISTER, GAS MASK,CHIN-TYPE,GMR-I-P100
815999 CANISTER,GAS MASK,CHIN TYPE,GMDL-C-95
816000 CANISTER, GAS MASK,CHIN-TYPE,GMHF-C-P100
816001 CANISTER,GAS MASK,GMA-N95,SUPER&IND.
816002 CANISTER,GAS MASK, GMD-N95, SUPER & IND.
816003 CANISTER,GAS MASK,GML-N95,SUPER&IND.
816009 CANISTER,GAS MASK,GMHS-SSW-N95,SUPER&IND
816010 CANISTER,GAS MASK,GMEO-SSW-N95,SUPER&IND
816051 CANISTER,GAS MASK,CHIN TYPE,GMF-C-N95
Super-Size and Industrial-Size Gas Masks

Features and Benefits

Full facepiece respiratory protection against certain gases and particulates
Chest-mounted canister
Rugged plastic carrying case

Principles of Operation

Upon inhalation, contaminated air enters the gas mask canister, where it is filtered before reaching the wearer, who breathes in only clean, fresh air. See Bulletin No. 1000-61, Key Elements of a Sound Respiratory Protection Program.

Approvals and Standards

All MSA gas masks are certified by the National Institute for Occupational Safety and Health (NIOSH). The specific numbers are shown under ordering information for each mask type.

WARNING: Do not use gas masks for fire fighting. Failure to follow this warning can result in serious personal injury or death.

Applications

Agriculture
Chemical
Electric Utility
Hazardous Materials
Oil and Gas
Paper & Pulp

Hazards

Toxic Atmosphere Non-IDLH

Product Information

Offer respiratory protection against a specific gas or group of gases, as indicated by canister identification. The gas mask assembly has the following Maximum Use Condition: Entry - 100x the Permissible Exposure Level; do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape - contaminant concentrations up to the maximum use concentration of the gas mask (generally, 20,000 ppm (2% by volume); see canister selection chart for details), providing there is adequate oxygen (19.5% by volume) to support life. At these upper use conditions, the service time may be as short as 12 minutes. The Super-Size gas mask has an extra-large canister, which will last approximately twice as long as the equivalent Industrial-Size canister because of a larger volume of chemical fill.

S.O.S. Rubber International Inc.
20283 State Road 7 Suite #400, Boca Raton, Florida 33498
Tel (561) 237-4247 | Fax (561) 237-4248 | email: info@sosrubberintl.com

We accept: