PERSONAL SAFETY
|
Industrial Gas Masks |
Chin-Type Gas Masks

Features and Benefits
Full
facepiece respiratory protection against certain gases and
particulates
Lightweight aluminum canister
Full line of canisters available
Principles of
Operation
Upon
inhalation, contaminated air enters the gas mask canister,
where it is filtered before reaching the wearer, who
breathes in only clean, fresh air.
Approvals and
Standards
The MSA
Chin-Type gas mask has been certified by the National
Institute for Occupational Safety and Health (NIOSH). The
specific numbers are shown under ordering information for
each mask type.
Applications
Agriculture
Chemical
Electric Utility
Paper & Pulp
Hazards
Toxic
Atmosphere Non-IDLH
Product
Information
Provides
respiratory protection against particulate matter, vapors
and gases by means of a lightweight, replaceable canister.
The small, oval-shaped aluminum canister and facepiece are
designed to permit downward head movement. This comfortable,
lightweight model is an alternative to the heavier models
and is designed for respiratory protection against a
specific gas or group of gases as indicated by canister
identification. The gas mask assembly has the following
Maximum Use Conditions: Entry - 100% the Permissible
Exposure Level; do not exceed the Immediately Dangerous to
Life and Health (IDLH) concentration. Escape - contaminant
concentrations up to the maximum use concentration of the
gas mask (generally 5,000 ppm (0.5%) by volume; see canister
selection chart for details), providing there is adequate
oxygen (19.5% by volume) to support life. At these upper use
conditions, the service time may be as short as 12 minutes.
Also available as a belt-mounted version which allows the
wearer to attach the canister to a belt clip and uses a
corrugated breathing tube to connect the canister to the
facepiece.
WARNING: Do
not use for fire fighting.
|
PN |
Description |
| 492827 |
BELT ASSY.URETHANE
PAPR |
| 817057 |
GAS MASK,GMA-C-N95
CANSTR |
| 817058 |
GAS MASK,GMA-C-N95
CANISTER |
| 817059 |
GAS MASK ASSY,CHIN
TYPE,GMC-C-N95,W/CASE |
| 817060 |
GAS MASK,GMC-C-N95
CANISTER |
| 817061 |
GAS MASK ASSY,CHIN
TYPE,GMF-C-N95,W/CASE |
| 817062 |
GAS MASK,GMF-C-N95
CANISTER |
| 817063 |
GAS MASK ASSY,CHIN
TYPE,GMD-C-N95,W/CASE |
| 817064 |
GAS MASK ASSY,CHIN
TYPE,GMD-C-N95 |
| 817065 |
GAS MASK ASSY,CHIN
TYPE,GML-C-N95,W/CASE |
| 817066 |
GAS MASK ASSY,CHIN
TYPE,GML-C-N95 |
| 9961 |
BELT
ASSY,WAIST,NYLON WEBBING,BLACK,52" |
|
Replacement
Canisters for Gas Masks

Principles of Operation
Upon
inhalation, contaminated air enters the gas mask canister,
where it is filtered before reaching the wearer, who
breathes in only clean, fresh air.
Approvals and
Standards
All MSA gas
masks are certified by the National Institute for
Occupational Safety and Health (NIOSH). The specific numbers
are shown under ordering information for each mask and
canister type.
Applications
Agriculture
Chemical
Electric Utility
Hazardous Materials
Oil and Gas
Paper & Pulp
Hazards
Toxic
Atmosphere Non-IDLH
Product
Information
Depending
upon the type and concentration of contaminant and length of
service time required, MSA offers three canister models,
including Type N or Super-Size, Industrial-Size and
Chin-Type. The canisters are seamless to prevent leakage or
channeling of gases/vapors past the chemical sorbents, kept
fresh by sealing tape on the bottom air intake, which also
prevents moisture from entering the canister before use.
They are easy to use and store because of their compact oval
shape, labeled as to type and limitations and are
color-coded for fast and accurate recognition.
|
PN |
Description |
| 815993 |
CANISTER, GAS MASK,
CHIN-TYPE, GMD-C-N95 |
| 815994 |
CANISTER,GAS
MASK,CHIN TYPE,GMA-C-N95 |
| 815995 |
CANISTER,GAS
MASK,CHIN TYPE,GML-C-N95 |
| 815996 |
CANISTER, GAS
MASK,CHIN-TYPE, GMC-C-N95 |
| 815998 |
CANISTER, GAS
MASK,CHIN-TYPE,GMR-I-P100 |
| 815999 |
CANISTER,GAS
MASK,CHIN TYPE,GMDL-C-95 |
| 816000 |
CANISTER, GAS
MASK,CHIN-TYPE,GMHF-C-P100 |
| 816001 |
CANISTER,GAS
MASK,GMA-N95,SUPER&IND. |
| 816002 |
CANISTER,GAS MASK,
GMD-N95, SUPER & IND. |
| 816003 |
CANISTER,GAS
MASK,GML-N95,SUPER&IND. |
| 816009 |
CANISTER,GAS
MASK,GMHS-SSW-N95,SUPER&IND |
| 816010 |
CANISTER,GAS
MASK,GMEO-SSW-N95,SUPER&IND |
| 816051 |
CANISTER,GAS
MASK,CHIN TYPE,GMF-C-N95 |
|
Super-Size and
Industrial-Size Gas Masks

Features and Benefits
Full
facepiece respiratory protection against certain gases and
particulates
Chest-mounted canister
Rugged plastic carrying case
Principles of
Operation
Upon
inhalation, contaminated air enters the gas mask canister,
where it is filtered before reaching the wearer, who
breathes in only clean, fresh air. See Bulletin No. 1000-61,
Key Elements of a Sound Respiratory Protection Program.
Approvals and
Standards
All MSA gas
masks are certified by the National Institute for
Occupational Safety and Health (NIOSH). The specific numbers
are shown under ordering information for each mask type.
WARNING: Do
not use gas masks for fire fighting. Failure to follow this
warning can result in serious personal injury or death.
Applications
Agriculture
Chemical
Electric Utility
Hazardous Materials
Oil and Gas
Paper & Pulp
Hazards
Toxic
Atmosphere Non-IDLH
Product
Information
Offer
respiratory protection against a specific gas or group of
gases, as indicated by canister identification. The gas mask
assembly has the following Maximum Use Condition: Entry -
100x the Permissible Exposure Level; do not exceed the
Immediately Dangerous to Life or Health (IDLH)
concentration. Escape - contaminant concentrations up to the
maximum use concentration of the gas mask (generally, 20,000
ppm (2% by volume); see canister selection chart for
details), providing there is adequate oxygen (19.5% by
volume) to support life. At these upper use conditions, the
service time may be as short as 12 minutes. The Super-Size
gas mask has an extra-large canister, which will last
approximately twice as long as the equivalent
Industrial-Size canister because of a larger volume of
chemical fill. |

S.O.S. Rubber International
Inc.
20283 State Road 7 Suite #400, Boca Raton, Florida 33498
Tel (561) 237-4247 | Fax (561) 237-4248 | email:
info@sosrubberintl.com
We accept:

|